  1. Back again. Could we please also have the option to disable the alert icon too. Basically we just want the block with the caption only.
  2. Yes, a central key/value repository would be useful, with universal access to keys via scripting in particular.
  3. Hi Michael, Is there a use case you have in mind?
  4. Agree. During an SDT it should be possible to suspend alerting and discovery. Also, ConfigSources should be suspended too.
  5. Have seen this is addressed in v100. Thank you!!
  6. I agree, I try to avoid using event sources because of the reasons you've stated. Your keying suggestion is similar to Netcool does it with its AlertKey field which can be configured as part of configuring the event collector in Netcool. Everytime an alert comes in with the same exact key, they are de-duplicated and the counter increased on the first occurrence alert. Alerts should have a last occurrence time stamp to show when the alert with the same key was last received, i.e. when the count last increased.
  7. Web services polling intervals go up to 10 minutes currently. Please add more, including hourly and 4 hourly options. My users would also like to be able to select the days on which to perform the tests, i.e. disable at weekends. (Not simply block alerts using SDT, but actually stop the polling.)
  8. Yep, I'd like this too. Could the textbox to edit the message also be made taller by default. I always need to drag the text box to make it taller to edit. Making it taller by default will save time.
  9. Please make the blue bar with the PRINT link an optional item to display. We often temporarily share dashboards for management to use in presentations and the blue "PRINT" bar takes up screen real-estate. I'd to have a checkbox that I can tick to hide the print option and blue bar in the dashboard sharing dialog.
  10. Hi, I have the following group hierarchy: Infrastructure Services/Primary/EMEA/Citrix Infrastructure Services/Primary/EMEA/Network Services Infrastructure Services/Primary/EMEA/Network Services/Routers Infrastructure Services/Primary/EMEA/Network ServicesSwitches Infrastructure Services/Primary/EMEA/Backups In an inventory report I want to include all devices except devices under "Network Services". I've tried numerous expressions and thought the following would be the one to go with: Infrastructure Services/Primary/EMEA/!(Network Services) But this still includes the devices in groups under Network Services. Any ideas?
  11. Please add an option to test RegEx filters in Data and Event sources. This could work like the "Test Script" option where we select a device from any in scope of the Applies To expression.
  12. Hi Matt, I'm after the instances in one request rather than getting the devices and having to make subsequent calls per devices.
  13. I agree too that updating DataSources presents a data loss risk. I've stopped updating DataSources now, unless we find a bug.
  14. Please make it possible to use the ##HOST## token in the logfile paths when configuring log file event sources. In the attached example, in our use case if we could use ##HOST## token (in place of the blue section of the path) then we could use a single logfile event source rather than having to clone the same one for each host.
  15. We've had incidents where people have set the wrong times for SDTs. It does not look good when we can lay the root cause blame on LogicMonitor for an incident.
  16. For Window Event EventSources please make the SOURCE the DataPoint. Having numeric event IDs as the DataPoint makes no sense to me since IDs can be the same for different SOURCEs. Better yet, I'd prefer to be able to map my own DataPoint label based on a combination of SOURCE and ID.
  17. Please make it possible to have independent alert trigger consecutive counts for status and response times when configuring a web service check. For example, I need to be able to alert on status after 2 checks fail, but only alert on response after 5 consecutive response time threshold violations.
  18. Hi, Is there a way to get all instances for given data source, but without having to provide device IDs? The REST API offers the following URI: URI: /device/devices/{deviceId}/devicedatasources/{deviceDatasourceId}/instances What I need is the equivalent of something like this: URI: /datasource/datasources/{datasourceId}/instances Which would return all instances for the datasource from all devices that have the datasource. The returned data should include the "managedObjectName" property so that from the instance we can refer back to a device.
  19. Please make it so that the device tree search function also searches in the system.sysname attribute.
  20. Hi @Sarah Terry Any update please as this is causing us a lot of confusion.
  21. If you are using a modern web browser (Chrome, Firefox, IE11+) you should be able to see the frame's URL in the browser's devtools, and then use that URL. More info about Chrome's dev tools here: https://developer.chrome.com/devtools
  22. What features are being targeted for Q2 2018? Would be good to some idea so we know if it'll be worth waiting or to build something ourselves now.